SCF-UN-15/125-11 at a glance
Key specifications
-
15 ± 1
Core Diameter (µm)
Diameter of the light-guiding core.
-
0.11 ± 0.01
Core Numerical Aperture
Light-acceptance angle of the core; with the core size, it sets how many modes are guided.
-
125 ± 2
Cladding Diameter (µm)
Outer diameter of the glass cladding.
-
< 10.0
Background Loss @ 1200 nm (dB/km)
Low background losses.
-
250 ± 15
Coating Diameter (µm)
Outer diameter of the protective polymer coating.
-
≤ 1
Core/Cladding Concentricity Error (µm)
Offset between the core and cladding centres; a low value eases splicing.
Description
The SCF-UN-15/125-11 features low background losses and excellent geometrical properties. It is designed for manufacturing passive components such as pump combiners and isolators when quasi-single-mode operation is required. These components are part of fiber lasers and amplifiers used in material processing applications.
Features & Benefits
- Compatible with industry-standard active fibers
- Low background losses
- Excellent geometrical properties
Applications
- Passive component manufacturing
- Fiber lasers and amplifiers
- Material processing
SCF-UN-15/125-11
Specifications
| Optical | |
|---|---|
| Core Numerical Aperture | 0.11 ± 0.01 |
| Background Loss @ 1200 nm (dB/km) | < 10.0 |
| Geometrical & Mechanical | |
| Core Diameter (µm) | 15 ± 1 |
| Cladding Diameter (µm) | 125 ± 2 |
| Core/Cladding Concentricity Error (µm) | ≤ 1 |
| Coating Diameter (µm) | 250 ± 15 |
SCF-UN-15/125-11